QR Code QR Code
Post Offer Free
Anytester (Hefei) Co., Ltd
Anytester (Hefei) Co., Ltd  

Gold Index: 65148

You are here: home  > Analytical Instrument  > Lab PID Gas Chromatography

Lab PID Gas Chromatography 

Payment Terms: T/T,L/C,D/A,D/P,WU 
Place of Origin: Hong Kong, China (Mainland) 
inquire skype
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail

Model No.: GC-4000
Production Capacity: 50 sets/month
Delivery Date: 2 ~ 4 weeks
Display: LCD and computer
Power supply: 110/220V, 60/50Hz
Product: Brand new
Means of Transport: Ocean,Land,Air
Packing: Wooden box
Brand Name: HY TECH
Type: Digital
Certificate: CO,CE
Hs Code: 9024.1090.00

1. Five detectors to choose, TCD, FID, FDP, NPD, ECD.
2. Stable temperature control system
3. Brand new pressure stabilization and multiple gas path

1.Application:

GC-4000A Series Laboratory PID Gas Chromatography are suitable for applications in analysis of gases, liquids,and mixture of gases and liquids. Our products are widely used in the fields of petroleum. chemical industry,coal mining, food, environmental sciences, pesticide, hygiene and epidemic prevention, quality inspection etc.

2.Detector Technical specification:

Detector

Sensitivity

Limit of detection

Noise

Linear range

Drift

TCD

S≥5000mv m1/mg


≤0.1mv



FID


M≤1×10-11g/sec (hexadecane)

≤5×10-14A

107

1×10-14A/30min

FPD


Mp≤2×10-12g/s Ms≤5×10-11g/s

≤2×10-12A

104

3×10-13A/30min

NPD


Mn≤5×10-13g/s;   Mp≤1×10-12g/s

≤2×10-13A

104

2.5×10-12A/h

ECD


M≤1×10-13g/ml   (γ ~ 666)

≤0.01mv

≥104

0.02mv/30min

3.Working Station Technical specification:

Item

Value

Measurement range

-1V ~ 1V

Measurement accuracy   (Linearity)

±2%

Sampling sensitivity

0.1μV/s

Number of Peaks   Measurable

20000

Max Chromatogram Storage

20 hours/sample

Repeatability (RSD)

Peak area: ±0.1%; Peak   height: ±0.2%

4.Models of GC-4000A Series Laboratory PID Gas Chromatography

Model

Application

Major configration

4001A

Macro Analysis of Gases and Liquids

TCD

4002A

General

FID + 8-ramp programmable heating

4003A

General

2 FIDs + 8-ramp programmable heating, 2 air routes

4004A

General

FID,TCD, 8-ramp programmable heating, 2 air   routes   

4005A

General

2 FIDs, TCD, 8-ramp programmable heating, 3 air   routes

4006A

Fully Automatic Analysis for Nature gases

2 FIDs, TCD, special column, capillary   column, one time auto-sampler, 8-ramp programmable heating, 3 air routes, 3   sets of 6-way values

4006B

Fully Analysis for Crude oil and natural gases

FID, TCD, 3 special columns, capillary column,   automatic back flushing system, 8-ramp programmable heating

4006C

Fully Analysis for Crude oil and natural gases

FID, TCD, 3 special columns, capillary column,   8-ramp programmable heating, 3 air routes, 6-way values

4006D

Analyzes dry gases and oil refinery gas, etc.

TCD, 2 packed columns, carriage gas switch system,   6-way value

4006E

Analyzes benzene and toluene in gasoline

TCD, 1 preparative column and 1 major column,   automatic back flushing system, inlet high temperature 6-way values

4006F

Analyzes categories of ether and alcohol in gasoline

FID, 1 preparative column and 1 major column, inlet   6-way value, precut and back flushing devices

4007A

Analyzes transformer oil FID

TCD, conversion oven, 2 specialized columns, 8-ramp   programmable heating, 2 air routes

4008A

Coal mining GC

2 FIDs, TCD, conversion oven, 3 special columns,   8-ramp programmable heating, 3 air routes, 3 sets of 6-way values

4008B

Coal mining GC 2 FIDs

TCD, conversion oven, 4 special columns, 8-ramp   programmable heating, 4 air routes, 4 sets of 6-way values

4009A

Environmental Monitoring, Hygiene and Epidemic   Prevention and food Inspection

FID, ECD, 8-ramp programmable heating, 2 air routes

4010A

Environmental Monitoring, Hygiene and Epidemic   Prevention and food Inspection

FID, FPD, 8-ramp programmable heating, 2 air routes

4011A

Environmental Monitoring, Hygiene and Epidemic   Prevention and food Inspection

FID, ECD, FPD, 8-ramp programmable heating, 3 air   routes

4012A

Analysis of Organic chlorine and other Material

ECD, 8-ramp programmable heating

4013A

Analysis of Organic phosphor and other material

NPD, 8-ramp programmable heating

4014A

General FID

NPD, 8-ramp programmable heating, 2 air routes

4015A

Environmental Monitoring, Hygiene and Epidemic   Prevention and food Inspection

TCD, NPD, 8-ramp programmable   heating, 2 air routes

4016A

Environmental Monitoring, Hygiene and Epidemic   Prevention and food Inspection

ECD, FPD, NPD, 8-ramp programmable   heating, 3 air routes

4017A

General

FID, ECD, NPD, 8-ramp programmable   heating, 3 air routes

4018A

Electronegative organics, organic phosphor analysis

ECD, NPD, 8-ramp programmable   heating, 2 air routes

4019A

General

TCD, FID, ECD, 8-ramp programmable   heating, 3 air routes

4020A

Organic sulfur and other organics analysis

FID, 8-ramp programmable   heating

4021A

General

2 FIDs, FPD, 8-ramp programmable   heating, 3 air routes

4022A

Macro analysis of gases, liquids and electronegative   substance

TCD, ECD, 8-ramp programmable   heating, 2 air routes

4023A

General

TCD, 2 FIDs, ECD, 8-ramp programmable   heating, 3 air routes

4024A

Organic sulfur and electronegative substance   analysis

ECD, FPD, 8-ramp programmable   heating, 2 air routes

4025A

Macro analysis of gases and liquids

2 TCDS, 8-ramp programmable   heating, 2 air routes

4026A

General

FID, FPD, NPD, 8-ramp programmable   heating, 2 air routes

4027A

Organic phosphor and organic sulfur analysis

FPD, NPD, 8-ramp programmable   heating, 2 air routes

4028A

Indoor air measurement

FID, 8-ramp   programmable heating,   thermal desorption system, capillary device

4029A

Indoor air measurement

2 FIDs, 8-ramp programmable   heating, thermal desorption system, capillary device

4030A

Indoor air measurement

TCD, FID, 8-ramp programmable   heating, thermal desorption system, capillary device

4031A

General

2 FIDs, ECD, 8-ramp programmable   heating, 3 air routes

4032A

Macro analysis of gases, liquids and organic sulfur

TCD, FPD, 8-ramp programmable   heating, 2 air routes

4033A

Macro analysis of gases

2 FIDs, conversion oven, 3 sets of 6-way values,   8-ramp programmable heating, 3 air routes

4034A

Macro and Micro Analysis of gases

FID, TCD, conversion oven, 2 sets 6-values, 8-ramp   programmable heating, 3 air routes

5.Standard Configuration of Laboratory PID Gas Chromatography:

No.

Item

1.          

Main machine

2.          

Software

3.          

Chromatogram columns

4.          

Interface board

5.          

Packing   list

6.          

Quality   certificate

7.          

User   manual 

6.Optional Configuration:

No.

Item

1.          

Chromatogram columns

2.          

PC

3.          

Printer

4.          

Air generator

5.          

Hydrogen generator

6.          

Multifunction generator

Mr. Eric Qin
skype Mr. Eric Qin
Sales Manager
Tel: 86-551-66191127
Fax: 86-551-68767677
Mobile: 183 5600 1869
Contact to this supplier

Didn't find what you're looking for? Post Buying Lead or contact HiSupplier Customer Service Center  for help!

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

Anytester (Hefei) Co., Ltd [China (Mainland)]


Business Type:Manufacturer, Trading Company, Distributor/Wholesaler, Service
City: Hong Kong Island
Province/State: Hong Kong
Country/Region: China (Mainland)

Follow Us: Follow us on facebook Follow us on linkedin Follow us on Twitter

Eric Qin:   skype
April King:   skype
Hy Tech:   qq

You May Like: