Anytester (Hefei) Co., Ltd
|
Payment Terms: | T/T,L/C,D/A,D/P,WU |
Place of Origin: | Hong Kong, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
1.Application:
GC-4000A Series Laboratory PID Gas Chromatography are suitable for applications in analysis of gases, liquids,and mixture of gases and liquids. Our products are widely used in the fields of petroleum. chemical industry,coal mining, food, environmental sciences, pesticide, hygiene and epidemic prevention, quality inspection etc.
2.Detector Technical specification:
Detector | Sensitivity | Limit of detection | Noise | Linear range | Drift |
TCD | S≥5000mv m1/mg | ≤0.1mv | |||
FID | M≤1×10-11g/sec (hexadecane) | ≤5×10-14A | 107 | 1×10-14A/30min | |
FPD | Mp≤2×10-12g/s Ms≤5×10-11g/s | ≤2×10-12A | 104 | 3×10-13A/30min | |
NPD | Mn≤5×10-13g/s; Mp≤1×10-12g/s | ≤2×10-13A | 104 | 2.5×10-12A/h | |
ECD | M≤1×10-13g/ml (γ ~ 666) | ≤0.01mv | ≥104 | 0.02mv/30min |
3.Working Station Technical specification:
Item | Value |
Measurement range | -1V ~ 1V |
Measurement accuracy (Linearity) | ±2% |
Sampling sensitivity | 0.1μV/s |
Number of Peaks Measurable | 20000 |
Max Chromatogram Storage | 20 hours/sample |
Repeatability (RSD) | Peak area: ±0.1%; Peak height: ±0.2% |
4.Models of GC-4000A Series Laboratory PID Gas Chromatography
Model | Application | Major configration |
4001A | Macro Analysis of Gases and Liquids | TCD |
4002A | General | FID + 8-ramp programmable heating |
4003A | General | 2 FIDs + 8-ramp programmable heating, 2 air routes |
4004A | General | FID,TCD, 8-ramp programmable heating, 2 air routes |
4005A | General | 2 FIDs, TCD, 8-ramp programmable heating, 3 air routes |
4006A | Fully Automatic Analysis for Nature gases | 2 FIDs, TCD, special column, capillary column, one time auto-sampler, 8-ramp programmable heating, 3 air routes, 3 sets of 6-way values |
4006B | Fully Analysis for Crude oil and natural gases | FID, TCD, 3 special columns, capillary column, automatic back flushing system, 8-ramp programmable heating |
4006C | Fully Analysis for Crude oil and natural gases | FID, TCD, 3 special columns, capillary column, 8-ramp programmable heating, 3 air routes, 6-way values |
4006D | Analyzes dry gases and oil refinery gas, etc. | TCD, 2 packed columns, carriage gas switch system, 6-way value |
4006E | Analyzes benzene and toluene in gasoline | TCD, 1 preparative column and 1 major column, automatic back flushing system, inlet high temperature 6-way values |
4006F | Analyzes categories of ether and alcohol in gasoline | FID, 1 preparative column and 1 major column, inlet 6-way value, precut and back flushing devices |
4007A | Analyzes transformer oil FID | TCD, conversion oven, 2 specialized columns, 8-ramp programmable heating, 2 air routes |
4008A | Coal mining GC | 2 FIDs, TCD, conversion oven, 3 special columns, 8-ramp programmable heating, 3 air routes, 3 sets of 6-way values |
4008B | Coal mining GC 2 FIDs | TCD, conversion oven, 4 special columns, 8-ramp programmable heating, 4 air routes, 4 sets of 6-way values |
4009A | Environmental Monitoring, Hygiene and Epidemic Prevention and food Inspection | FID, ECD, 8-ramp programmable heating, 2 air routes |
4010A | Environmental Monitoring, Hygiene and Epidemic Prevention and food Inspection | FID, FPD, 8-ramp programmable heating, 2 air routes |
4011A | Environmental Monitoring, Hygiene and Epidemic Prevention and food Inspection | FID, ECD, FPD, 8-ramp programmable heating, 3 air routes |
4012A | Analysis of Organic chlorine and other Material | ECD, 8-ramp programmable heating |
4013A | Analysis of Organic phosphor and other material | NPD, 8-ramp programmable heating |
4014A | General FID | NPD, 8-ramp programmable heating, 2 air routes |
4015A | Environmental Monitoring, Hygiene and Epidemic Prevention and food Inspection | TCD, NPD, 8-ramp programmable heating, 2 air routes |
4016A | Environmental Monitoring, Hygiene and Epidemic Prevention and food Inspection | ECD, FPD, NPD, 8-ramp programmable heating, 3 air routes |
4017A | General | FID, ECD, NPD, 8-ramp programmable heating, 3 air routes |
4018A | Electronegative organics, organic phosphor analysis | ECD, NPD, 8-ramp programmable heating, 2 air routes |
4019A | General | TCD, FID, ECD, 8-ramp programmable heating, 3 air routes |
4020A | Organic sulfur and other organics analysis | FID, 8-ramp programmable heating |
4021A | General | 2 FIDs, FPD, 8-ramp programmable heating, 3 air routes |
4022A | Macro analysis of gases, liquids and electronegative substance | TCD, ECD, 8-ramp programmable heating, 2 air routes |
4023A | General | TCD, 2 FIDs, ECD, 8-ramp programmable heating, 3 air routes |
4024A | Organic sulfur and electronegative substance analysis | ECD, FPD, 8-ramp programmable heating, 2 air routes |
4025A | Macro analysis of gases and liquids | 2 TCDS, 8-ramp programmable heating, 2 air routes |
4026A | General | FID, FPD, NPD, 8-ramp programmable heating, 2 air routes |
4027A | Organic phosphor and organic sulfur analysis | FPD, NPD, 8-ramp programmable heating, 2 air routes |
4028A | Indoor air measurement | FID, 8-ramp programmable heating, thermal desorption system, capillary device |
4029A | Indoor air measurement | 2 FIDs, 8-ramp programmable heating, thermal desorption system, capillary device |
4030A | Indoor air measurement | TCD, FID, 8-ramp programmable heating, thermal desorption system, capillary device |
4031A | General | 2 FIDs, ECD, 8-ramp programmable heating, 3 air routes |
4032A | Macro analysis of gases, liquids and organic sulfur | TCD, FPD, 8-ramp programmable heating, 2 air routes |
4033A | Macro analysis of gases | 2 FIDs, conversion oven, 3 sets of 6-way values, 8-ramp programmable heating, 3 air routes |
4034A | Macro and Micro Analysis of gases | FID, TCD, conversion oven, 2 sets 6-values, 8-ramp programmable heating, 3 air routes |
5.Standard Configuration of Laboratory PID Gas Chromatography:
No. | Item |
1. | Main machine |
2. | Software |
3. | Chromatogram columns |
4. | Interface board |
5. | Packing list |
6. | Quality certificate |
7. | User manual |
6.Optional Configuration:
No. | Item |
1. | Chromatogram columns |
2. | PC |
3. | Printer |
4. | Air generator |
5. | Hydrogen generator |
6. | Multifunction generator |